Imprimer

Sort Results

Vue liste Vue simple
SearchResultCount:"238023"
Description: Gooseneck splitless liner without wool, intermediate polarity deactivated, for trace, active samples <2 μl, 1/pack, For Bruker/Varian GCs 1177 inlets, Ø ext.: 6,5 mm, Ø int.: 4,0 mm, Longueur: 78,5 mm
Numéro de catalogue: REST21891
UOM: 1 * 1 ST
Fournisseur: Restek


Description: Open liner without wool, intermediate polarity deactivated, for trace, low volume samples, 25/pack, For Bruker/Varian GCs 1078/1079 inlets, Ø ext.: 5,0 mm, Ø int.: 0,75 mm, Longueur: 54 mm
Numéro de catalogue: REST21716
UOM: 1 * 25 ST
Fournisseur: Restek


Description: Frit splitter liner with glass frit, intermediate polarity deactivated, for dirty samples, non-active compounds, 1/pack, For Bruker/Varian GCs with 1075/1077 inlets, Ø ext.: 6,3 mm, Ø int.: 4,0 mm, Longueur: 72 mm
Numéro de catalogue: REST20715
UOM: 1 * 1 ST
Fournisseur: Restek


Description: Split liner without wool, intermediate polarity deactivated, for purge and trap inlet splitting or samples <1 μl, 1/pack, For Bruker/Varian GCs 1075/1077 inlets, Ø ext.: 6,3 mm, Ø int.: 1,0 mm, Longueur: 72 mm
Numéro de catalogue: REST20970
UOM: 1 * 1 ST
Fournisseur: Restek


Description: Cup splitter liner with top taper, intermediate polarity deactivated, for high and low MW compounds, 1/pack, For Bruker/Varian GCs with 1075/1077 inlets, Ø ext.: 6,3 mm, Ø int.: 4,0 mm, Longueur: 72 mm
Numéro de catalogue: REST20724
UOM: 1 * 1 ST
Fournisseur: Restek


Description: Low pressure drop liner with deactivated wool, intermediate polarity deactivated, for trace samples <2 μl and dirty samples, For Bruker/Varian GCs 1177 inlets, Ø ext.: 6,3 mm, Ø int.: 2,0 mm, Longueur: 78,5 mm
Numéro de catalogue: REST22421
UOM: 1 * 1 ST
Fournisseur: Restek


Description: Low pressure drop liner with deactivated wool, intermediate polarity deactivated, for trace samples <2 μl and dirty samples, 5/pack, For Bruker/Varian GCs 1177 inlets, Ø ext.: 6,3 mm, Ø int.: 2,0 mm, Longueur: 78,5 mm
Numéro de catalogue: REST22422
UOM: 1 * 5 ST
Fournisseur: Restek


Description: Drilled Uniliner® with hole near top, intermediate polarity deactivated, for trace, active samples, high recovery and linearity, 5/pack, For Bruker/Varian GCs 1177 inlets, Ø ext.: 6,3 mm, Ø int.: 4,0 mm, Longueur: 78,5 mm
Numéro de catalogue: REST21471
UOM: 1 * 5 Pce
Fournisseur: Restek


Description: Drilled Uniliner® with hole near top, intermediate polarity deactivated, for trace, active samples, high recovery and linearity, 1/pack, For Bruker/Varian GCs 1177 inlets, Ø ext.: 6,3 mm, Ø int.: 4,0 mm, Longueur: 78,5 mm
Numéro de catalogue: REST21470
UOM: 1 * 1 ST
Fournisseur: Restek


Description: Drilled Uniliner® with hole near bottom, intermediate polarity deactivated, for trace, active samples, high recovery and linearity, 1/pack, For Bruker/Varian GCs 1177 inlets, Ø ext.: 6,3 mm, Ø int.: 4,0 mm, Longueur: 78,5 mm
Numéro de catalogue: REST21468
UOM: 1 * 1 ST
Fournisseur: Restek


Description: SPI liner with buffer, without wool, intermediate polarity deactivated, dirty samples >1 μl fits for 0,25 mm 0,32 mm and 0,53 mm columns, 5/pack, For Bruker/Varian GCs, Ø ext.: 4,6 mm, Ø int.: 2,4 mm, Longueur: 54 mm
Numéro de catalogue: REST20851
UOM: 1 * 25 ST
Fournisseur: Restek


Description: SPI liner with buffer, without wool, intermediate polarity deactivated, dirty samples >1 μl fits for 0,25 mm 0,32 mm and 0,53 mm columns, 1/pack, For Bruker/Varian GCs, Ø ext.: 4,6 mm, Ø int.: 2,4 mm, Longueur: 54 mm
Numéro de catalogue: REST20850
UOM: 1 * 1 ST
Fournisseur: Restek


Description: Uniliner with top taper, intermediate polarity deactivated, for trace, active samples, high recovery and linearity, 1/pack, For Bruker/Varian GCs 1075/1077 inlets (use with 0,32 and 0,53 mm ID columns), Ø ext.: 6,3 mm, Ø int.: 4,0 mm, Longueur: 72 mm
Numéro de catalogue: REST20846
UOM: 1 * 5 ST
Fournisseur: Restek


Description: Uniliner with top taper, intermediate polarity deactivated, for trace, active samples, high recovery and linearity, 1/pack, For Bruker/Varian GCs 1075/1077 inlets (use with 0,32 and 0,53 mm ID columns), Ø ext.: 6,3 mm, Ø int.: 4,0 mm, Longueur: 72 mm
Numéro de catalogue: REST20345
UOM: 1 * 1 ST
Fournisseur: Restek


Description: SPI liner with buffer, without wool, intermediate polarity deactivated, dirty samples >1 μl fits for 0,25 mm 0,32 mm and 0,53 mm columns, 25/pack, For Bruker/Varian GCs, Ø ext.: 4,6 mm, Ø int.: 2,4 mm, Longueur: 54 mm
Numéro de catalogue: REST20852
UOM: 1 * 25 ST
Fournisseur: Restek


Description: Cyclo uniliner with top taper, for trace, dirty, high MW, active samples and linearity, intermediate polarity deactivated, 5/pack, For Bruker/Varian GCs 1075/1077 inlets (use with 0,32 and 0,53 mm ID columns), Ø ext.: 6,3 mm, Ø int.: 4,0 mm, Longueur: 72 mm
Numéro de catalogue: REST20348
UOM: 1 * 5 ST
Fournisseur: Restek