Imprimer

Votre recherche pour: Turbidimètres

Turbidity is used as a water quality indicator , particularly for drinking water. Turbidity meters measure the loss in light beam intensity as it passes through, of a fluid containing suspended particles. Ideally, for a water sample, the suspended particles should allow the incident light to scatter at an angle of 90 degrees with respect to the light source, however, according to the particle size, the angle of light differs. A smaller angle of scatter indicates larger particles and hence a highly turbid water sample. Supplying the calculated loss directly related to light particles scattering and absorbing, the tools come in desktop or portable styles. Boasting advanced features, the devices offer a high degree of ease while employed as well as reproducible results. The turbidity meters transport the collected data to other systems for further review. Turbidity is often measured by Nephelometric Turbidity Unit (NTU) or Formazin Turbidity Unit (FTU) and the dry-weight of suspended materials is indicated by Total Suspended Solids (TSS).

Turbidity is used as a water quality indicator , particularly for drinking water. Turbidity meters measure the loss in light beam intensity as it passes through, of a fluid containing suspended particles. Ideally, for a water sample, the suspended particles should allow the incident light to scatter at an angle of 90 degrees with respect to the light source, however, according to the particle size, the angle of light differs. A smaller angle of scatter indicates larger particles and hence a highly turbid water sample. Supplying the calculated loss directly related to light particles scattering and absorbing, the tools come in desktop or portable styles. Boasting advanced features, the devices offer a high degree of ease while employed as well as reproducible results. The turbidity meters transport the collected data to other systems for further review. Turbidity is often measured by Nephelometric Turbidity Unit (NTU) or Formazin Turbidity Unit (FTU) and the dry-weight of suspended materials is indicated by Total Suspended Solids (TSS).


39  les résultats ont été trouvés

Sort Results

Vue liste Vue simple
SearchResultCount:"39"
Description: Turbidimètre, Turbiquant® 1100, Tungsten
Numéro de catalogue: 1.18325.0001
UOM: 1 * 1 ST
Fournisseur: Merck

MSMD


Description: Turbidimètre, Turbiquant® 1100 IR, Infrared
Numéro de catalogue: 1.18324.0001
UOM: 1 * 1 ST
Fournisseur: Merck

MSMD


Description: Turbidimètre, TIR 210
Numéro de catalogue: 705-1166
UOM: 1 * 1 ST
Fournisseur: VWR Collection


Description: Turbidimètre
Numéro de catalogue: 705-1104
UOM: 1 * 12 ST
Fournisseur: VWR Collection


Description: Set d'étalonnage StabCal® avec RFID (10 ; 20 ; 600 NTU/FNU)
Numéro de catalogue: HACHLZY835
UOM: 1 * 1 ST
Fournisseur: Hach


Description: Cylindre de vérification d'étalon secondaire (0,1 NTU)
Numéro de catalogue: HACHLZY901
UOM: 1 * 1 ST
Fournisseur: Hach


Description: Turbidimètre de paillasse, TU5, Plage de mesure: 0 - 1000 NTU / FNU / TE/F / FTU ; 0 - 100 mg/L ; 0 - 250 EBC
Numéro de catalogue: HACHLPV4429903022
UOM: 1 * 1 ST
Fournisseur: Hach


Description: Set d'étalonnage StabCal® sans RFID (10 ; 20 ; 600 NTU/FNU)
Numéro de catalogue: HACHLZY898
UOM: 1 * 1 ST
Fournisseur: Hach


Description: Flacon d'étalonnage StabCal® sans RFID (20 NTU)
Numéro de catalogue: HACHLZY899
UOM: 1 * 1 ST
Fournisseur: Hach


Description: Flacon d'étalonnage StabCal® avec RFID (20 NTU)
Numéro de catalogue: HACHLZY837
UOM: 1 * 1 ST
Fournisseur: Hach


Description: Turbidimètre portable, Turb® 430, Tungsten halogen
Numéro de catalogue: 705-0672
UOM: 1 * 1 ST
Fournisseur: WTW


Description: Turbidimètre portable, Turb® 430 T, Tungsten halogen
Numéro de catalogue: 662-2147
UOM: 1 * 1 ST
Fournisseur: WTW


Description: Turbidimètre portable, Turb® 430, Infrared LED
Numéro de catalogue: 705-1027
UOM: 1 * 1 ST
Fournisseur: WTW


Description: Turbidimètre portable, Turb® 430, Infrared LED
Numéro de catalogue: 705-0671
UOM: 1 * 1 ST
Fournisseur: WTW


Description: Turbidimètre, TL 2350, Lampe à filament de tungstène, Plage de mesure: 0 - 10 000 NTU
Numéro de catalogue: 705-0984
UOM: 1 * 1 ST
Fournisseur: Hach


Description: Turbidimètre, TL 2300, Lampe à filament de tungstène, Plage de mesure: 0 - 4000 NTU
Numéro de catalogue: 705-0982
UOM: 1 * 1 ST
Fournisseur: Hach


1 - 16 of 39