The capillary electrophoresis systems separate mixture molecules based on individual size and charge. Applying a voltage to the buffer solutions, the influenced ions migrate with the electrical field through the narrow-bore tubes at different rates. Containing highly sensitive electrodes, the capillary electrophoresis systems promote the movement of anions toward anodes and the cathodes to attract cations. This analytical technique yields quicker results and partitioning with higher resolution than other methods.

The capillary electrophoresis systems separate mixture molecules based on individual size and charge. Applying a voltage to the buffer solutions, the influenced ions migrate with the electrical field through the narrow-bore tubes at different rates. Containing highly sensitive electrodes, the capillary electrophoresis systems promote the movement of anions toward anodes and the cathodes to attract cations. This analytical technique yields quicker results and partitioning with higher resolution than other methods.


56  les résultats ont été trouvés

SearchResultCount:"56"

Sort Results

Vue liste Vue simple

Évaluez le résultat de cette recherche

Numéro de catalogue: (HEWLG1600-62318)
Fournisseur: Agilent
Description: CEP coated capillaries contain a permanently bonded polymer coating. This CEP coating shields the silanol functionality of the capillary surface and helps prevent sample adsorption. Additionally, EOF is nearly eliminated, making the capillary ideal for applications such as DNA separations with sieving polymer buffers.
UOM: 1 * 2 ST


Fournisseur: Agilent
Description: PVA coated capillaries contain a permanently adsorbed layer of polyvinyl alcohol. This coating minimises hydrophobic and electrostatic solute/wall interactions and eliminates electroosmotic flow (EOF). Using a proprietary deposition process, the PVA coating is stable over a wide pHrange, even under basic conditions from 2,5 to 9,5. This stability allows the use of many common CE buffers. Because the silica surface is covered, many proteins and amines can be analysed without the peak tailing found with uncoated capillaries. In addition, since EOF is eliminated, cumbersome washing procedures are unnecessary and migration time reproducibility may be improved.

Fournisseur: Agilent
Description: Système d'électrophorèse capillaire (CE), accessoire, Spare part, Filtre en verre, solvant d'admission, 20 μm

Fournisseur: Agilent
Description: These fused silica capillaries are designed to analyte mixtures are separated and the components detected via UV-Vis absorption, allowing preliminary identification based on peak elution time and UV-Vis spectra or both, when compared to a standard.

Fournisseur: Agilent
Description: CE/MS sprayer kit and CE/MS adapter kit to couple an Agilent CE instrument with an MS system.

Fournisseur: VARIAN
Description: A series of coated capillaries specifically designed for CE, which are prepared by cross-linking and bonding a novel, proprietary fluorocarbon (FC) polymer. μSIL-FC capillaries are chemically inert, hydrophobic, and stable from pH 2,5 to 10.

Fournisseur: Agilent
Description: Alignment interfaces are an integral part of the Agilent diode-array detection (DAD) system. These interfaces contain optical slits which are precisely matched to the capillary inner diameter for optimised sensitivity and linear detection range.

Fournisseur: Agilent
Description: Agilent Technologies extended light path capillaries ('bubble' cell capillaries) can be used to improve sensitivity 3- to 5-fold over standard capillaries. With extended light path capillaries, the inner diameter is increased only at the detection window, offering the sensitivity of a wide inner diameter capillary and the low current generation of a narrow one.

Appel de prix
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l'call est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 016 385 011
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l'call est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 016 385 011
Ces articles ne peuvent être ajoutés au Panier. Veuillez contacter votre service client ou envoyer un e-mail à vwr.be@vwr.com
Une documentation supplémentaire peut être nécessaire pour l'achat de cet article. Un représentant de VWR vous contactera si nécessaire.
Ce produit a été bloqué par votre organisation. Contacter votre service d'achat pour plus d'informations.
Le produit original n'est plus disponible. Le remplacement représenté est disponible
Les produits marqués de ce symbole ne seront bientôt plus disponibles - vente jusqu'à épuisement de stock. Des alternatives peuvent être disponibles en recherchant le code article VWR indiqué ci-dessus. Si vous avez besoin d'une assistance supplémentaire, veuillez contacter notre Service Clientèle au 016 385 011.
49 - 56 of 56
no targeter for Bottom